Specifications
Type |
Parallel type |
|||
8-bit type |
||||
Model No. |
DMH-GB1 |
DMH-GB2 |
DMH-HB1 |
DMH-HB2 |
Transmission capacity(I/O) |
8BIT/8BIT |
|||
Direction |
HEAD-ON |
SIDE-ON |
||
Transmission distance |
0.6m |
3m |
0.6m |
3m |
Directional angle |
±15° |
±5° |
±15° |
±5° |
Transmission method |
Half-duplex two-way transmission |
|||
Transmission time |
7msec |
|||
Modulation method |
FSK modulation |
|||
Detection method |
Bit-reverse comparison system |
|||
Power source |
18 to 30VDC(ripple 10% or less) |
|||
Current consumption |
100mA Max. |
|||
Ambient illuminance |
10,000lux or less |
|||
Ambient temperature/ humidity |
-10 to +50 degrees C, 85%RH or less |
|||
Vibration resistance |
Double amplitude 1.5mm, 10 to 30Hz, each 2 hour in X, Y and Z directions |
|||
Impact resistance |
500m/s2, each 10 time in X, Y and Z directions |
|||
Connection |
Lead wire (0.2mm2, 23 cores, shield cable 2m long) |
|||
Protective structure |
IP64(IEC standard) |
|||
External dimension
DMH-GB1, DMH-GB2(HEAD-ON type)

DMH-HB1, DMH-HB2(SIDE-ON type)

Input/output circuit
Input

Flow current when ON(IO) : approx. 5mA(when 24VDC)
Allowable residual voltage when ON : use it with 1.8V or less
Output


NPN open-collector output
35DC 50mA residual voltage 1.5V or less
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
*1 MODE input
This is to choose transmission/reception mode when standing by
*Transmission stand-by mode by opened between mode and I/O COM
*Reception stand-by mode by short-circuited between mode and I/O COM
Note) If one side is set to transmission stand-by mode, other one should be set to reception standby mode.
*2 SELECT input
This is to stop transmission/reception optionally by outer signal
*Operating by opened between select and I/O COM
*Stopping by short-circuited between select and I/O COM
*3 GO output
This is to check correct optical single
*ON when receiving correct optical axis
*OFF when interrupting optical axis(Not-receiving)
*4 Strobe
It is getting ON when data is fixed.
Note) The connector attached can't be used as relay terminal.