Home > Products > Optical Data Transmission Devices > CWF-01/02

Optical Data Transmission Devices | Photo sensor | Auto counter | Automatic door

SERIAL TYPE

A4 size print

CWF-01/02

OPTICAL DATA TRANSMISSION DEVICE

CWF-01/02

Transmission distance 50m, Small size and Light weight

Feature

  • Necessary specifications are built-in 40x80x80mm. This is suitable for the application such as automatic warehouse, stacker crane or overhead crane as well as BWF series.

Specifications

Model No.

CWF-01A

CWF-01B

CWF-02A

CWF-02B

Transmission distance

50m

Directional angle

±2°

Power source

24VDC(+10%,-10%)

Current consumption

80mA

Transmission method

Full-duplex two-way transmission

Transmission speed

DC to 19,200bps

DC to 9,600bps

Interface

RS-422

RS-232C

Modulation method

FSK modulation

Modulated frequency

Transmission:5.5MHz
Reception:6.0MHz

Transmission:6.0MHz
Reception:5.5MHz

Transmission:5.5MHz
Reception:6.0MHz

Transmission:6.0MHz
Reception:5.5MHz

Connection

D-sub connector with 9-pin

Ambient temperature/humidity

-10 to +50 degrees C, 85%RH or less(not icing)

Ambient illuminance

20,000lux or less(Halogen/incandescent lamp)

Impact resistance

490m/s2, each 10 time in X, Y and Z directions

Vibration resistance

Double amplitude 1.5mm, 10 to 55Hz, each 2 hour in X, Y and Z directions

Noise resistance

Impulse noise simulator, pulse width:1µ, 100ns, repeated cycle:100Hz, normal mode 1000V, common mode 500V

Protective structure

IP60(IEC standard)

Warning output(ARM)

ON when light-receiving level margin 1.5 times or more, Photo-coupler, open-collector 35V, 50mA

Weight

Approx. 240g

* Multi-connection type with CS(Chip select) input which can be connected up to max.10 pcs is lined-up.
* 12VDC type is available.

External dimension

Input/output circuit

CWF-01A/01B

CWF-02A/02B

Connection

CWF-01A/01B

Interface

Pin No.

Symbols

Functions

RS-422

1

+RD

Reception data

2

-RD

3

+SD

Transmission data

4

-SD


5

SG

Ground for signal

Power source

6

+VIN

DC power(24VDC)

7

-VIN(0V)

Warning

8

ARM

Warning output (ARM)

9

ARM COM

CWF-02A/02B

Interface

Pin No.

Symbols

Functions

RS-232C

1

CD

Reception data(Carrier detect)

2

RD

Transmission data

3

SD

Reception data

4

NC

Non-connection


5

SG

Ground for signal

Power source

6

+VIN

DC power(24VDC)

7

-VIN(0V)

Warning

8

ARM

Warning output (ARM)

9

ARM COM

Note) Don't connect 0V(-VIN) for power source to ground for signal(SG).