DMM-GB/HB |
OPTICAL DATA TRANSMISSION DEVICE |
|
|
This device is able to connect directly to CC-Link system. |
Specifications
|
Model No. |
DMM-GB1 |
DMM-HB1 |
DMM-GC1 |
DMM-HC1 |
||||||||||||||||||
|
Direction |
HEAD-ON |
SIDE-ON |
HEAD-ON |
SIDE-ON |
||||||||||||||||||
|
Power source |
24VDC(18 to 30VDC available) |
|||||||||||||||||||||
|
Optical communication part |
Transmission distance |
0 to 1m*1 |
0 to 3m*2 |
|||||||||||||||||||
|
Directional angle |
Full angle 30° |
Full angle 26° |
||||||||||||||||||||
|
Transmission capacity(I/O) |
8BIT/8BIT |
16BIT/16BIT*3 |
||||||||||||||||||||
|
Transmission method |
Half-duplex two-way transmission |
|||||||||||||||||||||
|
Transmission time |
40ms |
|||||||||||||||||||||
|
Modulation method |
Pulse modulation |
FSK modulation |
||||||||||||||||||||
|
Detection method |
Parity check |
|||||||||||||||||||||
|
CC-Link part |
Transmission speed |
10Mbps/5Mbps/2.5Mbps/625kbps/156kbps(Changeover by switch) |
||||||||||||||||||||
|
Communication system |
Polling system |
|||||||||||||||||||||
|
Synchronous system |
Frame synchronous system |
|||||||||||||||||||||
|
Transmission path |
RS-485bus |
|||||||||||||||||||||
|
Remote station Nos. |
1 to 64 |
|||||||||||||||||||||
|
Occupied station |
1 station |
|||||||||||||||||||||
|
Connecting cable |
CC-Link exclusive cable and CC-Link high quality cable |
|||||||||||||||||||||
|
Max. extending cable*4 |
|
|||||||||||||||||||||
|
Connecting system |
Connector type(5 pins) |
|||||||||||||||||||||
|
Ambient temperature/ humidity |
-10 to +50 degrees C, 85%RH or less(Not condensing) |
|||||||||||||||||||||
|
Ambient illuminance |
Halogen 4,000 lx or less, mercury lamp 4,000 lx or less |
|||||||||||||||||||||
*1. 3m type is also available.
*2. Distance can be changed by adjuster.
*3. 16th bit can be changed to Select input/GO output by input changeover switch.
*4. Total extended distance changes depending on total
External dimension
External dimension

Connection

5P side(CC-Link connection)
|
Signals |
Functions |
Position |
|
DA |
Signal cable |
1 |
|
DAR |
Terminator provided |
2 |
|
DB |
Signal cable |
3 |
|
DG |
Signal GND cable |
4 |
|
SLD |
Shield cable |
5 |
Note) If this device is connected to terminator, it is shorted between DA and DAR by the wire with 1mm.
3P side(Power source)
|
Signals |
Functions |
Position |
|
FG |
Ground |
1 |
|
+24V |
DC power |
2 |
|
+0V |
DC power |
3 |