Home > Products > Photo sensor > PH-BH1-81

Optical Data Transmission Devices | Photo sensor | Auto counter | Automatic door

Sensor for special applications/Textile

A4 size print

PH-BH1-81

Sensors for Textile Industry Built-in amplifier type photoelectric switch(8-beam type)

Photo sensor:PH-BH1-81

Sensor
PH-BH1-81

 
コントロールユニット:EA5-1221

Control unit
EA5-1221

コントロールユニット:EA5-1222

Control unit
EA5-1222

Close monitoring for sliver breakage

This is 8 beams reflection type sensor which was developed for detecting sliver breakage of drawing frame s. As the sliver is checked one by one, it is possible to check accurately. Also, it is to detect stably against up/down or right direction because of enough for detecting characteristic.

Specifications

Sensor

Kind

Diffuse-reflection type

Model No.

PH-BH1-81

Power source

12 to 24VDC ±10%(Ripple 5% or less)

Current consumption

200mA(at 12VDC)

Light source

Infra-red LED

Detecting distance

20 to 80mm(sliver with φ20mm)

Output

NPN open-collector output(allowable load voltage 33V or less, allowable load current 100mA or less, residual voltage 0.5V)

Response time

Approx. 500msec

Indicators

Light-entering lamp : red LED(Lights up when light-entering)
Sliver-missing detecting lamp: red LED(Lights up when sliver missing)

Connection

Cable type(2m long, 0.3mm2)

Ambient illuminance

Incandescent lamp : 3,000lx or less

Ambient temperature/humidity

竏鈀10 degrees C to +50 degrees C, 45 to 85%RH

Vibration resistance

Double amplitude 1.5mm, 10 to 33Hz, Each 2 hour in X, Y and Z directions

Impact resistance

200m/s2, Each 3 time in X, Y and Z directions

Protective structure

IP50(IEC standard)

Case materials

Case : steel plate(cover : acrylic PBT)

Weight

Approx. 1.4kg


Control unit

Kinds

32-beam type

16-beam type

Model No.

EA5-1221

EA5-1222

Connectable numbers

4 pcs of PH-BH1-81

2 pcs of PH-BH1-81

Power source

AC100 to 110V/AC200 to 220V(±10%, 50/60Hz) 

Power consumption

10VA or less

5VA or less

Power for sensor

DC10 to 15V 1A

DC10 to 15V 0.5A

Control output

1C relay and 1a relay(250VAV 4A cosφ=1)

Connection

Screw terminal(M3)

Ambient temperature/humidity

竏鈀10 degrees C to +50 degrees C, 45 to 85%RH

Vibration resistance

Double amplitude 1.5mm, 10 to 33Hz, Each 2 hour in X, Y and Z directions

Impact resistance

200m/s2, Each 3 time in X, Y and Z directions

Protective structure

IP40(IEC standard)

Case materials

Case : steel plate(SPCC)

Weight

Approx. 1.3 kg

Approx. 1.1 kg

External dimension

Sensor(PH-BH1-81)

The pitch of each light beam can be set from 25mm to 40mm.
It can adjust the sensitivity as per each light beam.
PH-BH1-61 for 6-beam type is also available.


Control unit(EA5-1221/EA5-1222)

Connection

EA5-1221

EA5-1222

 

Operation

 

When normal sliver

 

Light-entering lamp on the sensor is lighting up. Sliver breakage lamp is going off.

 

  Control output between 4 & 5 } ………… "Open"
    between 7 & 8
    between 5 & 6 …………… "Open"

 

 

When sliver breakage

 

Sensor for sliver breakage become s non-light-entering state and light-entering lamp goes off and sliver breakage lamp lights up.

 

  Control output between 4 & 5 } ………… "Close"
    between 7 & 8
    between 5 & 6 …………… "Close"

 

Note) Sliver breakage lamp and output is self-holding circuit and is keep this state till reset or cutting power source.

 

Reset(Releasing holding state)

 

Breakage lamp and output is released by "Close" between 9 & 13.

PAGE TOP