UST-05LN causes chattering. Is there any countermeasure?
UST-05LN causes chattering. Is there any countermeasure?
If it is chattering, please make the area larger or smaller than now.
Another method is to set the hysteresis. Hysteresis expands the area at a fixed rate when it detects an object within the area. When the object is no longer detected in the area, it will revert to the original area setting.
Relation
-
Does the range sensor (PBS / UST / UAM) use OSSD?
-
Why is the spread of the light beam different from the front and the side of the LiDAR?
-
Does the laser beam of UST-05LN decrease due to deterioration over time?
-
Will water droplets on the surface of the UST-10LX optical window affect data acquisition?
-
What kind of output is synchronous output?
FAQ's Category
- Photoelectric Switch
- 3D LiDAR
- Area Configuration Type
- Optical Data Transmission Device
- Sensor for Iron and Steel Industry
- Area Configulation Type
- Optical Remote Control Device
- Auto Counter
- Sensor for Textile Industry
- Application
- Laser Range Finder
- Scanning Range Finder (Data Output Type)
- Scanning Range Finder (Area Configuration Type)
FAQ's Tag
- YVT
- DMS
- PLX
- post_tag-195
- ISL
- UST
- EWF
- FG
- DM
- PD5
- URM
- BWF
- VMH
- PDL
- CWF
- UAM
- DMM
- MBX
- PNX
- DWF
- PX1
- UGM
- MFG
- DMH
- PA-SC2
- PHE
- UBG
- PB9
- LX1
- DMC
- PHF
- URG
- post_tag-163
- LAD
- BNC
- DMJ
- MBF
- LAV
- PL1
- PCF
- DMG
- EH8
- LX2
- PA-S
- MC-A201
- KAD
- HSA
- PR
- BRS
- PH-DX
- PBS
- PH
- PD
- DMF
- S-20
- UXM
- LEX
- AC
- ISP
- RS controller
- FBX
- PEX
- PA
- KRG
- HMPD
- BRC
- EP1
- PFX
- UTM
- LA
- DC
- PK7
- PG
- PGL
- FHM
- FC
- PEY
- DME