A4 size print

PVF


Optical fiber type photo sensor

PVF

Large & Easy-to-see Indicators!
Large Sensitivity Adjuster!

Feature

  • Accessory such as screw driver for sensitivity adjuster is not required because large-sized adjuster is provided
  • Fiber insertion indicator is provided
  • It is easy to see stable level lamp and output lamp because of large size
  • NPN and PNP output type are lined-up
  • Off-delay timer(40msec) is provided

Specifications

Model No.

PVF-CR

PVF-CRA

Power source

10 to 30VDC(Ripple 10% or less)

Current consumption

25mA

Light source

Red LED

Operating mode

Changeover of LIGHT-ON/DARK-ON

Control output

NPN open-collector output
100mA/30VDC or less, 1.8V/100mA or less

PNP open-collector output
100mA/30VDC or less, 1.8V/100mA or less

Response time

250µsec or less

Timer function

OFF-delay(Fixed 40msec)

Sensitivity adjustment

Sensitivity adjustment

Indicators

Stable level lamp(Green LED), output lamp(Orange LED)

Connecting method

Cable type, 2m long(φ3.8mm, 3-core cable)

Ambient illuminance

Incandescent lamp : less than 3,000lx, sun light : less than 10,000lx

Ambient temperature/ humidity

竏鈀25 to +55 degrees C,35% to 85%RH(when using), 35% to 95%(when stored)

Insulation resistance

20MΩ or less(by 500VDC)

Withstand voltage

1,000VAC, 50/60Hz/min.

Vibration resistance

Double amplitude 1.5mm, 10 to 55Hz

Impact resistance

500m/s2, each 3 time for X, Y and Z direction

Protective structure

IP66(IEC standard)

Case material

Case : PBT resin, cover : polycarbonate , approx. 70g(including cable)

Accessory

Bracket

Mounting

DIN-rail

External dimension

Sensor


Bracket

Output circuit

NPN output

PNP output


Caution
(1) Don't make a parallel wiring with high voltage and power cable or don't use the same wiring tube. It may cause malfunction by induction.
(2) When using a commercial switching regulator as power source, ground FG(Frame ground terminal) and G(Ground terminal).
(3) A transit state is kept about 0.1 sec. Don't make any detecting during this period.