KAD-300 |
Distance measurement type close crane warning device |
|
|
Optical type Distance Sensor
|
Feature
- It is easy to set optional detecting distance by pushing the button for distance setting.
- It always makes a self-diagnosis with inner circuit and it prevent the troubles beforehand.
- It is easy to make an optical axis with 5-point level meter.*
* KAD-200(20m type) is lined-up, too..
Specifications
|
Model No. |
KAD-300 |
|
|
Power source |
100 to 240VAC(+15%, -10%, 50/60Hz) |
|
|
Power consumption |
10VA or less when 100VAC, 15VA or less when 200VAC |
|
|
Detecting distance |
1 to 30m |
|
|
Detectable objects |
Reflector(RRP-KAD01) |
|
|
Eirectional angle |
±2.5° |
|
|
Output |
Control output |
1C relay(250VAC 3A, cosφ=1) Relay isn't excited and LED lights up when within setting distance |
|
Trouble output(FAULT) |
1C relay(250VAC 3A, cosφ=1) Relay isn't excited and LED lights up or flickers when light-emitting/receving amount is getting lower or troubled |
|
|
Absolute precision /Repeatability |
±800mm, ±400mm |
|
|
Hysteresis |
500mm |
|
|
Resolution |
160mm |
|
|
Response time |
50msec or less*1 |
|
|
Connection |
M4 screw terminal(15 pins) |
|
|
Ambient illuminance |
10,000lx or less(Halogen and mercury light), 6,000lx(incandescent lamp: Max.illuminance) |
|
|
Ambient temperature/humidity |
-10 degrees C to +55 degrees C, 85%RH or less(not condensing, not icing) |
|
|
Vibration resistance |
Double amplitude 1.5mm, 10 to 55Hz, each 2 hour for X, Y and Z direction |
|
|
Impact resistance |
490m/s2 (50G), each 10 time for X, Y and Z direction |
|
|
Case materials |
Steel plate(SPCC) |
|
|
Weight |
Approx.3kg |
|
*Don't operate during 2sec after putting power source on.
External dimension
●Sensor

●Reflector(RRP-KAD01)

External connection

Output
Control output(OUT 1, 2 and 3)
|
Terminal No. |
1―2 |
2―3 |
4―5 |
5―6 |
7―8 |
8―15 |
|
|
Power-OFF state |
OPEN |
CLOSE |
OPEN |
CLOSE |
OPEN |
CLOSE |
|
|
Power-ON state |
Within setting distance |
OPEN |
CLOSE |
OPEN |
CLOSE |
OPEN |
CLOSE |
|
Over setting distance |
CLOSE |
OPEN |
CLOSE |
OPEN |
CLOSE |
OPEN |
|
Trouble output(FAULT)
|
Terminal No. |
9―10 |
10―11 |
|
|
Power-OFF state |
OPEN |
CLOSE |
|
|
Power-ON state |
When normal |
CLOSE |
OPEN |
|
When troubled |
OPEN |
CLOSE |
|