PDA |
|
|
|
Both Control output and analog output provide |
Feature
- Built-in amplifier and low-cost
- High precision detection can be made by applying PSD(Position Sensitive Detector)
- Protective structure is IP67
- Easy setting(Upper limit and lower limit) can be made by pushing teaching button
- Wide line-up with 30mm to 250mm(4 kinds) as detection distance
Specifications
|
Model No. |
PDA-03KT |
PDA-10KT |
PDA-13KT |
PDA-25KT |
|
|
Detecting range |
30±4mm |
100±35mm |
130±50mm |
250±150mm |
|
|
Spot diameter(Center) |
φ0.5mm |
1×1.5mm |
1×1.5mm |
1.5×2.5mm |
|
|
Resolution*1 |
1µm/100ms |
15µm/100ms |
20µm/100ms |
150µm/100ms |
|
|
3µm/10ms |
50µm/10ms |
70µm/10ms |
500µm/10ms |
||
|
10µm/1ms |
150µm/1ms |
200µm/1ms |
1,500µm/1ms |
||
|
Light source |
Visible semi-conductor laser(Wavelength : 650nm, 3.3mW or less, Class 2) |
||||
|
Power source |
12 to 24VDC(-5 to +10%) |
||||
|
Current consumption |
120mA at 12VDC, 75mA or less at 24VDC |
||||
|
Resolution of open-collector output |
Resolution of analog output + Hysteresis |
||||
|
Linearity*2 |
±2%FS |
±3.5%FS |
±5%FS |
||
|
Temperature drift |
±0.02%FS/degrees C |
||||
|
Response time |
100ms/10ms/1ms by changeover switch |
||||
|
Sensitivity changeover |
Set/FIX/Auto by changeover switch |
||||
|
Function |
Handling mode |
Set/Run/RUN Off-delay Position switch |
|||
|
Detection range setting |
2-point teaching system |
||||
|
Offset adjusting range |
Analog output can be fixed to 12.00mA at optional point within detectable range |
||||
|
Input |
Blanking input |
Provided |
|||
|
Remote teaching |
Provided |
||||
|
Output |
Analog output |
4 to 20mA |
|||
|
Control output |
NPN open-collector output 30V, 100mA or less |
||||
|
Timer |
Off-delay 40ms by changeover switch |
||||
|
Ambient temperature/humidity |
-10 degrees C to +40 degrees C, 35 to 85%RH |
||||
|
Warming-up time |
15 min. or less |
||||
*1 In case of the center of detecting range, AUTO sensitivity and alumina ceramic
*2 Supplementation of linearity : Error from linearity of analog current when detecting white alumina ceramic
External dimension

Connection