Home > Products > Photo sensor > MBX-211

Optical Data Transmission Devices | Photo sensor | Auto counter | Automatic door

Sensors for special applications/Iron and Steel Industry

A4 size print

MBX-211
Sensors for Iron and Steel Industry

Microwave type
Close crane warning device

MBX-211

Detecting accuracy is high because of geometrical setting system

Feature

  • This is a microwave overhead traveling close crane warning device. Consisting of two sets of transmitter/receiver
    installed oppositely, when two cranes approach each other until the both detecting areas overlap, the microwave of the opposite side is mutually detected, and an alarm signal is executed.

Specifications

Model No.

MBX-211

Power source

100 to 110VAC/200 to 220VAC(±10%, 50/60Hz)

Current consumption

3.5VA or less

Detecting range

0 to 20m when installing angle is 20°(Recommended)
10 to 40m when installing angle is 45°(Max.)

Hysteresis

15% or less of detecting distance

Control output

1C relay contact(250VAC 5A, 30VDC 5A, cosφ=1)

Response time

50msec or less(400msec or less when returned)

Alarm output*

1C relay contact(250VAC 5A, 30VDC 5A, cosφ=1)

Indication lamps

Power, operation, trouble(Normal, transmission trouble, reception trouble)

Sensitivity adjuster

Course adjuster : 5 steps(10dB), fine adjuster : 10dB

Connection

M4 screw terminal, applicable wire 3.5mm2

Ambient temperature/humidity

-10 degrees C to +55 degrees C, 45 to 85%RH

Vibration resistance

10 to 55Hz Double amplitude 1.5mm Each 2 hour in X, Y and Z directions

Impact resistance

196m/s2 (20G) Each 10 time in X, Y and Z directions

Case

Steel plate

Weight

Approx. 12kg

* In case that reception level is lowered to 1/4, it is executed after approx. 10 sec.
Note) If using it outside, it may malfunction because trouble output would be executed by heavy rain or typhoon. Use the rain-proof cover as option.

External dimension

Connection

Control output

Terminal No.

6-7

7-8

Power-OFF state

OPEN

CLOSE

Power-ON state

When non-detection

CLOSE

OPEN

When detection

OPEN

CLOSE

Trouble output

Terminal No.

9-10

10-11

Power-OFF state

CLOSE

OPEN

Power-ON state

When normal

OPEN

CLOSE

When troubled

CLOSE

OPEN

PAGE TOP