DC-M |
LED display DIN size |
|
|
Easy operation, clear display & easy pre-set |
Feature
- All models provide increment/decrement counting and this counter can apply to wide range of application because of free voltage, 100 to 240VAC.
Specifications
72×72mm type
|
Type |
Increment/decrement type total counter |
Increment/decrement type preset counter |
|
Model No. |
DC-MA6-D |
DC-MB6-D |
|
Display |
Red LED(changeover by green and orange LED) |
|
|
Number of digit |
6 digits |
|
|
Power source |
100 to 240VAC(50/60Hz) |
|
|
Fluctuation range |
-15% to +10% |
|
|
Power consumption |
Approx. 4.5VA(when 240VAC) |
|
|
Counting |
Contact/transistor open-collector input : Counting when OFF→ON, voltage input: Counting when “L”→“H” |
|
|
Preset |
|
1 |
|
Preset method |
|
Digital switch for each digit |
|
Counting speed |
30Hz: Min. signal width 16.7msec, make-ratio 1:1 |
|
|
Counting prohibited |
Prohibited when ON("H" level in case of voltage input)Response time: 16msec or less(when 30Hz), 100μsec or less(when 5kHz) |
|
|
Counting/ reset/counting prohibited input |
Contact/transistor open-collector input Impedance(ZON): 1kΩ or less when ON(Short-circuit), Impedance(ZOFF): 5kΩ or more when OFF(Opened) |
|
|
Control output operation |
Self-holding operation: It operates when preset value and returns by reset |
|
|
Power source for sensor |
12VDC(+10%, -10%), 100mA(Ripple 5% or less) |
|
|
Ambient temperature, humidity |
-10 degrees C to +45 degrees C(-20 degrees C to +55 degrees C when stored) 45 to 85%RH |
|
|
Memory time against power failure |
Memory time/once: approx. 10 years, memory numbers: 0.1 million times |
|
|
Case |
Case: ABS resin, dust-proof cover: polycarbonate |
|
|
Attachment |
Dust-proof cover, fitting metal |
|
72×144mm type
|
Type |
Increment/decrement type total counter |
Increment/decrement type preset counter |
Increment/decrement type 2-preset counter |
|
Model No. |
DC-MA6-E |
DC-MB6-E |
DC-MC6-E |
Display |
Red LED(changeover by green and orange LED) |
||
|
Number of digit |
6 digits |
||
|
Power source |
100 to 240VAC(50/60Hz) |
||
|
Fluctuation range |
-15% to +10% |
||
|
Power consumption |
約4.5VA(when 240VAC) |
||
|
Counting |
Contact/transistor open-collector input : Counting when OFF→ON, voltage input: Counting when “L”→“H” |
||
|
Preset |
|
1 |
2 |
|
Preset method |
|
Digital switch for each digit |
|
|
Counting speed |
30Hz: Min. signal width 16.7msec, make-ratio 1:1 |
||
|
Counting prohibited |
Prohibited when ON("H" level in case of voltage input)Response time: 16msec or less(when 30Hz), 100μsec or less(when 5kHz) |
||
|
Counting/ reset/counting prohibited input |
Contact/transistor open-collector input Impedance(ZON): 1kΩ or less when ON(Short-circuit), Impedance(ZOFF): 5kΩ or more when OFF(Opened) |
||
|
Control output operation |
Self-holding operation: It operates when preset value and returns by reset |
||
|
Power source for sensor |
12VDC(+10%, -10%), 100mA(Ripple 5% or less) |
||
|
Ambient temperature, humidity |
-10 degrees C to +45 degrees C(-20 degrees C to +55 degrees C when stored) 45 to 85%RH |
||
|
Memory time against power failure |
Memory time/once: approx. 10 years, memory numbers: 0.1 million times |
||
|
Case |
Case: ABS resin, dust-proof cover: polycarbonate |
||
|
Attachment |
Dust-proof cover, fitting metal |
||
* DC-MOW with BCD read-out output is also lined up. Ask us in details.。
External dimension
72×72mm type |
|
![]() |
![]() |
|
72×144mm type |
|
![]() |
![]() |
|
Connection
Input/transister output
|
Contact/transister open-collector input |
Voltage input |
![]() |
![]() |
Connection
DC-M_Connection 72×72mm type
Contact/Open-collector input

Note) Count 1 terminal [8] is increment, Count 2 terminal [9] is decrement. In case of 90 phase-difference input, when Count 1 is shifted shifted by 90°, it is increment counting, and when Count 2 is shifted 90°, it is decrement counting.
Note) In case of Total counter, [4] [5] [6] terminal are not used.
Note) FG [3] terminals should be grounded.
DC-M_Connection 2×144mm type
Contact/Open-collector input

Note) Terminals [11] and [18] are connected inside
Note) Count 1 [12] is increment counting and Count 2 [13] is decrement counting. In case of 90°phase-difference input, when Count 1 is shifted by 90°, it is increment counting, and when Count 2 is shited by 90°, it is decrement counting.
Note) In case of total counter, [4] [5] [6] [7] [8] [9] [16] [17] terminals are not used.
Note) In case of preset counter (1 preset type), [4] [5] [6] [16] terminals are not used.
Note) FG ([3] terminal) should be grounded.
Caution note)
* Do not use unused terminal as relay terminal.
* Each input to counting, reset and count prohibition is common use for contact and open-collector. Wire to each input and output terminal 2-core shield wire or metal conduit tube as short as possible. Do not lay the wires close to or parallel to line cable, power cable or high voltage line.
* For connection, use M3 pressure connection terminals.