Will there be mutual interference if DMS and UTM are installed nearby?

I have installed DMS-GF1A-02 or DMS-GF1B-02 near UTM-30LX. Will they interfere with each other?

DMS is affected by the UTM laser beam, so communication error may occur depending on the timing. Depending on the conditions, the data of UTM also may deteriorate only in a specific step (the part where receives the light of DMS). To prevent mutual interference, the UTM's light beam is 30 m and 400 mm in the vertical direction, so please keep it twice as far away. If the distance is 15m, double the distance by 200mm.