How to Use
FEATURE DETAIL
How to UseSensor for Iron and Steel Industry

Optical axis adjustment (HMD)

Optical axis adjustment of optical fiber type HMD

(1) When installing the sensor head, take a look from above against ambient light (sunlight, incandescent light).


(2) Align the mechanical axis with the sight of the sensor head.


(3) Check the value with and without a heat material by confirming the analog voltage value or level display (8 points) , and verify the influence of ambient light and residual heat.


(4) If the detected heat material is large and has a high temperature, a radiant heat is reflected by rollers or side guides, and sensor may operate even if the heat material is outside of the detection field. Pay attention to prevent reflected light.