Products Detail
PVF
Photoelectric SwitchFiber-Optic
This product is no longer in production or sales.
Large & Easy-to-see Indicators!
Large Sensitivity Adjuster!
Overview
Features
-> Accessory such as screw driver for sensitivity adjuster is not required because large-sized adjuster is provided
-> Fiber insertion indicator is provided
-> It is easy to see stable level lamp and output lamp because of large size
-> NPN and PNP output type are lined-up
-> Off-delay timer(40msec) is provided
-> Fiber insertion indicator is provided
-> It is easy to see stable level lamp and output lamp because of large size
-> NPN and PNP output type are lined-up
-> Off-delay timer(40msec) is provided
Specification
Model No. | PVF-CR | PVF-CRA |
Power source | 10 to 30VDC(Ripple 10% or less) | |
Current consumption | 25mA | |
Light source | Red LED | |
Operating mode | Changeover of LIGHT-ON/DARK-ON | |
Control output | NPN open-collector output 100mA/30VDC or less, 1.8V/100mA or less |
PNP open-collector output 100mA/30VDC or less, 1.8V/100mA or less |
Response time | 250µsec or less | |
Timer function | OFF-delay(Fixed 40msec) | |
Sensitivity adjustment | Sensitivity adjustment | |
Indicators | Stable level lamp(Green LED), output lamp(Orange LED) | |
Connecting method | Cable type, 2m long(φ3.8mm, 3-core cable) | |
Ambient illuminance | Incandescent lamp : less than 3,000lx, sun light : less than 10,000lx | |
Ambient temperature/ humidity | -25 to +55 degrees C,35% to 85%RH(when using), 35% to 95%(when stored) | |
Insulation resistance | 20MΩ or less(by 500VDC) | |
Withstand voltage | 1,000VAC, 50/60Hz/min. | |
Vibration resistance | Double amplitude 1.5mm, 10 to 55Hz | |
Impact resistance | 500m/s2, each 3 time for X, Y and Z direction | |
Protective structure | IP66(IEC standard) | |
Case material | Case : PBT resin, cover : polycarbonate , approx. 70g(including cable) | |
Accessory | Bracket | |
Mounting | DIN-rail |
External dimension
Sensor
Bracket
I/O Circuit
NPN output
PNP output
Caution
(1) Don`t make a parallel wiring with high voltage and power cable or don`t use the same wiring tube. It may cause malfunction by induction.
(2) When using a commercial switching regulator as power source, ground FG(Frame ground terminal) and G(Ground terminal).
(3) A transit state is kept about 0.1 sec. Don`t make any detecting during this period.
(1) Don`t make a parallel wiring with high voltage and power cable or don`t use the same wiring tube. It may cause malfunction by induction.
(2) When using a commercial switching regulator as power source, ground FG(Frame ground terminal) and G(Ground terminal).
(3) A transit state is kept about 0.1 sec. Don`t make any detecting during this period.
Downloads
Before Download
Only members can download the file.
If you have not registered as a member, please register as a member by clicking the "Registration".
If you are already a member, please agree to the following terms and click the "Agree".
If you have not registered as a member, please register as a member by clicking the "Registration".
If you are already a member, please agree to the following terms and click the "Agree".
License for Downloading Materials
When downloading the product specifications, drawings and various types of materials and software related to the Hokuyo's product line, please read the terms of use in advance and then utilize the same with your understanding and consent. In case of dissent, please understand that you cannot register to and be recognized in the download page. (And the Terms of Use may be revised without prior notice.)
Terms of Use
- Intellectual Property Rights
-
- Copyrights and the other rights to contents such as sentences, data and software published on this Website (hereinafter referred to as "Contents") are held by Hokuyo or its suppliers.
- The secondary application (copy, diversion, defacement, analysis, transmission, assignment, rental, licensing, and usage for the purpose of business activities or commercial gain) of the Contents on this Website posted by Hokuyo is strictly prohibited without our prior approval. Specific terms of use described for each download site or Contents shall apply in preference to the Terms of Use.
- Provision of the Contents on this Website by Hokuyo means neither a transfer of the patent rights, design rights, and/or the other intellectual property rights to inventions and designs in the Contents, nor a grant of any rights based on the intellectual property rights.
- Disclaimer
-
Hokuyo pays full attention to the information that appears on this Website, but does not take responsibility for the following items:
- The information that appears on this Website is always the latest version, and is updated or corrected timely and properly;
- The information that appears on this Website is accurate, useful and safe;
- Customer's damage incurred by the use of this Website, including changes or deletions of the information, discontinuation or suspension of the publication; and
- Any and all damage incurred by using this Website.
Product's Category
- Scanning Rangefinder
- Photoelectric Switch
- Sensor for Iron & Steel Industry
- Optical Data Transmission Device